347550402
|
1032500
|
2024-08-27
|
2000 YAMHILL ROAD, BOISE, ID, 83716
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-08-27
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2024-11-25 |
Current Penalty |
2742.5 |
Initial Penalty |
5485.0 |
Final Order |
2024-12-13 |
Nr Instances |
1 |
Nr Exposed |
14 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the struck-by or crushing hazards when operating a forklift without the use of a restraint device: a) On August 27th, 2024 and at time prior thereto; employees operated the Toyota TWF-13004 S/N 53756 without the use of a seatbelt due to the latch of the seatbelt being broken. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2024-11-25 |
Abatement Due Date |
2025-01-14 |
Current Penalty |
4840.0 |
Initial Penalty |
9680.0 |
Final Order |
2024-12-13 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On August 27th, 2024, and at time prior thereto; employees change the dies on the Chicago Model 410-D, SN P8627 120-ton press brake and are exposed to amputation hazards. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2024-11-25 |
Abatement Due Date |
2025-01-14 |
Current Penalty |
5646.0 |
Initial Penalty |
11292.0 |
Final Order |
2024-12-13 |
Nr Instances |
3 |
Nr Exposed |
20 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On August 27th, 2024, and at time prior thereto; employees used the Mighty Industries Osama lathe, SN 320057 to shape and size metal pieces. b) On August 27th, 2024, and at time prior thereto; employees used the Lagun Republic Mill to drill holes in metal pieces. c) On August 27th, 2024, and at time prior thereto; employees used the Chicago Model 410-D, SN P8627 120-ton press brake to bend metal brackets. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100213 P04 |
Issuance Date |
2024-11-25 |
Abatement Due Date |
2024-12-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-13 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(p)(4): The unused run of the sanding belt was not guarded against accidental contact. a) Rail Department: On August 27th, 2024, and at time prior thereto; employees used the Heller Grinder belt sander to smooth and debur material. The metal housing on top of the sander had an opening of approximately 2 inches wide and 8 inches long. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2024-11-25 |
Abatement Due Date |
2024-12-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-13 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) On August 27th, 2024, and at time prior thereto; employees used the Central Machinery 8" bench grinder, which was missing the adjustable tongue, to sharpen tools. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2024-11-25 |
Current Penalty |
2419.5 |
Initial Penalty |
4839.0 |
Final Order |
2024-12-13 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. a) On August 27th, 2024, and at time prior thereto; a compressed air nozzle measured a pressure of 108 p.s.i. when dead ended. |
|
|
341499986
|
1032500
|
2016-05-25
|
11420 W EXECUTIVE DR, BOISE, ID, 83713
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-05-25
|
Case Closed |
2016-07-21
|
Related Activity
Type |
Complaint |
Activity Nr |
1091109 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2016-06-15 |
Current Penalty |
1500.0 |
Initial Penalty |
2400.0 |
Final Order |
2016-07-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) TIG welding area: On and before May 25 2016, work rest on 8" bench grinder were one half inch from the wheel. Boise Metal Works Inc was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.215(a)(4) that was contained in OSHA Inspection 283482, Citation 1, Item 2b, issued on 7/20/2012; Final order date of 8/7/2012 with respect to the work site 11345 President Dr. , Boise, Idaho. Note: Abatement certification is NOT required for this item. Corrected during inspection. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2016-06-15 |
Current Penalty |
0.0 |
Initial Penalty |
2400.0 |
Final Order |
2016-07-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a)TIG welding area: On and before May 25, 2016, the tongue guards on 8" bench grinder used to sharpen welding material were adjusted to one half inch from the abrasive wheel. Boise Metal Works Inc was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.215(b)(9) that was contained in OSHA Inspection 283482, Citation 1, Item 2c, issued on 7/20/2012; Final order date of 8/7/2012 with respect to the work site 11345 President Dr. , Boise, Idaho. Note: Abatement certification is NOT required for this item. Corrected during inspection. |
|
|
333302131
|
1032500
|
2012-04-04
|
11345 PRESIDENT DRIVE, BOISE, ID, 83713
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-04-04
|
Case Closed |
2013-07-10
|
Related Activity
Type |
Complaint |
Activity Nr |
218549 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101052 D02 |
Issuance Date |
2012-07-16 |
Abatement Due Date |
2012-08-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride: (a) On or about April 4, 2012 and at times prior thereto, employees were using Harris 1620 Nozzle Shield Anti-Spatter spray (73-84% methylene chloride) without having had initial monitoring done to determine how much methylene chloride they were exposed to. Note: Abatement certification is required |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2012-07-16 |
Abatement Due Date |
2012-08-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about April 4, 2012 and at times prior thereto, the employer had not written and implemented a hazard communication program for employees working chemicals, such as but not limited to, Harris Anti-spatter (73-84% Methylene Chloride). Note: Abatement certification is required. |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2012-07-16 |
Abatement Due Date |
2012-08-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) On or about April 4, 2012 and at times prior thereto, employees had not been properly trained on the hazards associated with chemicals such as but not limited to Anti-Spatter spray containing 73-84% methylene chloride. Note: Abatement certification is required. |
|
|
332834829
|
1032500
|
2012-03-27
|
11345 PRESIDENT DRIVE, BOISE, ID, 83713
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-03-28
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2012-10-25
|
Related Activity
Type |
Complaint |
Activity Nr |
218549 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-08-03 |
Current Penalty |
1275.0 |
Initial Penalty |
2550.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of crushing injuries while operating powered industrial trucks: a) On or about 3/27/2012, and at times prior thereto, the Nissan LPG powered industrial truck did not have a seatbelt installed. Note 1: Abatement certification is required. Note 2: One feasible and acceptable abatement method to correct this hazard is to install a seat belt. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100178 L03 I M |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-08-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(3)(i)(M): Any other operating instructions, warnings, or precautions listed in the operator's manual for the types of vehicle that the employee is being trained to operate. a) At the shop: On or about 3/27/2012, and at times prior thereto, the employer did not provide operators with instructions, warnings or other precautions for the Nissan LPG powered industrial truck. Note: Abatement certification is required. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100178 L06 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: a) At the shop; On or about 3/27/2012, and at times prior thereto, the employer did not have a list of certified trained powered industrial truck operators with the date of their last evaluation. Note: Abatement certification is required. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-08-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1):A powered industrial truck was found to be in need of repair, defective, or in any way unsafe, the truck was not taken out of service until it has been restored to safe operating condition. a) At the shop: On or about 3/27/2012, and at times prior thereto, the Nissan LPG powered industrial truck transmission would not stay in gear. b) At the shop; On or about 3/27/2012, and at times prior thereto, the Gradall rough terrain powered industrial truck had a broken window that was held with duct tape. Note: Abatement certification is required. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 A02 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
765.0 |
Initial Penalty |
1530.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(2): The safety guard did not cover the spindle end, nut, and flange projections. The safety guard was not mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard: a) At the shop; On or about 3/27/2012, and at times prior thereto, the safety guard on the spindle end of the Baldor bench grinder was missing. Note: Abatement certification is required. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): On offhand grinding machines, work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch (0.125 inches) to prevent the work from being jammed between the wheel and the rest: a) In the shop: On or about 3/27/2012,, and at times prior thereto, the work rest on the Baldor bench grinder was 4/8 inches from the grinding wheel. Note: Abatement certification is required. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): Safety guards were not adjusted so that the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch: a) At the shop: On or about 3/27/2012, and at times prior thereto, the tongue guard of the Baldor bench grinder was missing. Note: Abatement certification is required. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100036 D01 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
16 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employees were unable to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors: a) At the south east corner of the shop: On or about 3/27/2012, and at times prior thereto, the exit door was secured by a large barrel bolt. Note: Abatement certification is required. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100037 B02 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit." a) At the south east corner of the shop: on 3/27/2012, and at times prior thereto, the exit did not have an exit sign. Note: Abatement certification is required. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100147 C01 |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-08-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was isolated from the energy source and rendered inoperative: a) The shop: On or about 3/27/2012, and at times prior thereto, energy control procedures (lock out/tag out) had not been developed for equipment such as but not limited to the water jet cutter, iron worker, shear, brake, powered industrial trucks, and band saws. Note: Abatement certification is required. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100212 A03 II |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, were not guarded. The guarding device was not in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, was not so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a) At the shop; On or about 3/27/2012, and at times prior thereto, the Black and Decker 10 inch Chop saw was missing the lower blade guard. Note: Abatement certification is required. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100242 B |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
2 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air was used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) In the shop: On or about 3/27/2012, and at times prior thereto compressed air used for cleaning was 70 pounds per square inch at the tip of the nozzle. (b) In the shop: On or about 3/27/2012, and at times prior thereto, compressed air used for cleaning was 100 pounds per square inch at the tip of the nozzle. Note: Abatement certification is required for this item. |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 II |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(i)(C): The work space was not clear and extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of this section. However, other equipment associated with the electrical installation and located above or below the electric equipment may extend not more than 153 mm (6 in.) beyond the front of the electric equipment: a) The distribution panel in the north east corner of the shop: On or about 3/27/2012, and at times prior thereto, the area in front of the circuit breaker panel box was obstructed by scrap metal, empty cardboard boxes and lumber. Note: Abatement certification is required. |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19100334 A02 I |
Issuance Date |
2012-07-20 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-07 |
Nr Instances |
2 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated. a) In the shop: On or about 3/27/2012, and at times prior thereto, the power cord on the Milwaukee right angle grinder was missing the ground pin. b) In the shop: On or about 3/27/2012, and at times prior thereto, the Ellis band saw power cord was missing the ground pin and was damaged. Note: Abatement certification is required. |
|
|