Name: | TCA ROOFING, LLC |
Jurisdiction: | Idaho |
Legal type: | Limited Liability Company (D) |
Status: | Inactive-Dissolved (Administrative) |
Date of registration: | 30 Nov 2006 (18 years ago) |
Financial Date End: | 30 Nov 2024 |
Date dissolved: | 22 Feb 2025 |
Entity Number: | 181385 |
Place of Formation: | IDAHO |
File Number: | 181385 |
ZIP code: | 83301 |
County: | Twin Falls County |
Principal Address: | APT A 276 ADAMS ST TWIN FALLS, ID 83301-4966 |
Mailing Address: | PO BOX 64 WENDELL, ID 83355-0064 |
Name | Role | Address |
---|---|---|
FERNANDO ESPINOZA | Agent | 4355 N 2100 E, FILER, ID 83328 |
Name | Role | Address | Appointed On |
---|---|---|---|
TCA R LLC | Member | P.O. BOX 64, WENDELL, ID 83355 | 2020-10-12 |
Ma D Carrillo | Member | 4355 N 2100 E, FILER, ID 83328 | 2023-10-16 |
Santos A Espinoza | Member | 4355 N 2100 E, FILER, ID 83328 | 2023-10-16 |
Filing Name | Filing Number | Filing date |
---|---|---|
Dissolution/Revocation - Administrative | 0006117307 | 2025-02-22 |
Annual Report | 0005441542 | 2023-10-16 |
Annual Report | 0004985196 | 2022-11-07 |
Annual Report | 0004474605 | 2021-11-01 |
Annual Report | 0004030266 | 2020-10-12 |
Restatement of Certificate of Organization of LLC | 0003650930 | 2019-10-18 |
Annual Report | 0003638476 | 2019-10-03 |
Application for Reinstatement | 0003457154 | 2019-03-21 |
Dissolution/Revocation - Administrative | 0003442212 | 2019-03-05 |
Annual Report | 0001639882 | 2017-10-17 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342218310 | 1032500 | 2017-03-23 | 132 MAIN AVE S, TWIN FALLS, ID, 83303 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1198098 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260502 B10 |
Issuance Date | 2017-04-10 |
Abatement Due Date | 2017-05-04 |
Current Penalty | 923.5 |
Initial Penalty | 1847.0 |
Final Order | 2017-05-05 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(b)(10): Each employee engaged in roofing activities on low-slop roofs, with unprotected sides and edges 6 feet (1.8m) or more above lower levels was not protected from falling by a guardrail system, safety net system, personal fall arrest system, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. (a) On or about March 23, 2017, and at times prior thereto, employees were observed working on a flat roof probing the seams on a rubber membrane roof without a fall protection system in place. Note: Abatement certification IS required for this item. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2017-04-10 |
Current Penalty | 923.5 |
Initial Penalty | 1847.0 |
Final Order | 2017-05-05 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about March 23, 2017, and at times prior thereto, employees involved in roofing activities utilized an extension ladder to access a flat roof that extended only 1 1/2 foot over the parapet wall. Note: Abatement certification IS NOT required for this item |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2009-08-21 |
Emphasis | L: FALL, S: COMMERCIAL CONSTR, S: STRUCK-BY, S: FALL FROM HEIGHT |
Case Closed | 2013-04-26 |
Related Activity
Type | Complaint |
Activity Nr | 200250470 |
Safety | Yes |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2009-12-04 |
Abatement Due Date | 2009-12-31 |
Current Penalty | 450.0 |
Initial Penalty | 450.0 |
Nr Instances | 1 |
Related Event Code (REC) | Complaint |
Gravity | 01 |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2009-12-04 |
Abatement Due Date | 2009-12-10 |
Current Penalty | 1500.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2009-12-04 |
Abatement Due Date | 2009-12-31 |
Nr Instances | 1 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
Date of last update: 01 Apr 2025
Sources: Idaho Secretary of State