347153249
|
1032500
|
2023-12-08
|
SOUTH SCHOOL AVE, KUNA, ID, 83634
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-12-08
|
Emphasis |
N: TRENCH
|
Case Closed |
2024-08-20
|
Related Activity
Type |
Complaint |
Activity Nr |
2110254 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
2024-03-26 |
Abatement Due Date |
2024-04-19 |
Current Penalty |
0.0 |
Initial Penalty |
3702.0 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) On or about December 8, 2023, an employee used the walls and a pipe to exit the excavation which had nearly vertical walls, and measured approximately 5'6" deep, 5'7" long, and 3'4" wide. |
|
Citation ID |
01003A |
Citaton Type |
Other |
Standard Cited |
19260651 J02 |
Issuance Date |
2024-03-26 |
Abatement Due Date |
2024-04-19 |
Current Penalty |
0.0 |
Initial Penalty |
10163.0 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2):Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) On or about December 8, 2023, an employee was working in an excavation with the spoil pile placed directly at to within one foot of the edge of the excavation. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2024-03-26 |
Abatement Due Date |
2024-04-19 |
Current Penalty |
6098.0 |
Initial Penalty |
0.0 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. (a) On or about December 8, 2023, an employee was not protected from cave-in hazards while working in an excavation with nearly vertical walls, measuring approximately 4.5 ft to 5.5 feet deep, 5'7" long, and 3'4" wide. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2024-03-26 |
Abatement Due Date |
2024-04-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-05-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c) a) On or about December 8, 2023 an employee was not protected from cave-in hazards while working in an excavation with nearly vertical walls, measuring approximately 4.5 ft to 5.5 feet deep, 5'7" long, and 3'4" wide. |
|
|
346940737
|
1032500
|
2023-08-25
|
2700 E OVERLAND RD, MERIDIAN, ID, 83642
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-08-25
|
Emphasis |
N: CTARGET, N: HEATNEP, P: HEATNEP
|
Case Closed |
2023-10-03
|
|
346128853
|
1032500
|
2022-08-05
|
1077 S SILVERSTONE WAY, MERIDIAN, ID, 83642
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-08-05
|
Emphasis |
N: TRENCH, P: TRENCH
|
Case Closed |
2023-01-13
|
Related Activity
Type |
Inspection |
Activity Nr |
1612878 |
Safety |
Yes |
|
|
343049680
|
1032500
|
2018-03-27
|
205 8TH AVENUE WEST, MARSING, ID, 83639
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-06-06
|
Emphasis |
N: TRENCH
|
Case Closed |
2022-09-26
|
Related Activity
Type |
Complaint |
Activity Nr |
1322311 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2018-07-09 |
Abatement Due Date |
2018-08-02 |
Current Penalty |
5174.0 |
Initial Penalty |
5174.0 |
Contest Date |
2018-08-02 |
Final Order |
2019-05-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation are not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c) of this section. a) On or about March 27, 2018 and at times prior thereto employees were working in a trench between 5.5 to 6 feet deep in type B soil, where adequate cave in protection was not used. NOTE: Abatement certification and documentation are required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260651 J01 |
Issuance Date |
2018-07-09 |
Abatement Due Date |
2018-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2018-08-02 |
Final Order |
2019-05-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face: a) On or about March 27, 2018 and at times prior thereto employees were working in a trench 5 feet and deeper, where loose rocks, soil, and chunks of pavement were at the edge of the excavation wall, directly above exposed employees. NOTE: Abatement certification is required for this item. |
|
|
342297900
|
1032500
|
2017-05-03
|
1101 W FRONT ST, BOISE, ID, 83702
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-05-03
|
Emphasis |
N: TRENCH
|
Case Closed |
2022-09-26
|
Related Activity
Type |
Complaint |
Activity Nr |
1208499 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1229838 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
2017-11-01 |
Abatement Due Date |
2017-11-02 |
Current Penalty |
8873.0 |
Initial Penalty |
8873.0 |
Contest Date |
2017-11-15 |
Final Order |
2019-06-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) Two employees of Alta Construction, Inc. were not provided a safe means of egress while working in an excavation located along Myrtle Avenue between 11th Street and 12th Street in Boise, ID measuring approximately 80' long by approximately 7.5' wide and approximately 6.7' - 7.7' deep on or about May 3, 2017, and at times prior thereto, exposing them to cave-in hazards. NOTE: Abatement certification AND supporting documentation are required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 K02 |
Issuance Date |
2017-11-01 |
Abatement Due Date |
2017-11-02 |
Current Penalty |
0.0 |
Initial Penalty |
8873.0 |
Contest Date |
2017-11-15 |
Final Order |
2019-06-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety. (a) Employees working in an excavation located along Myrtle Avenue between 11th Street and 12th Street in Boise, ID measuring 80' long by approximately 7.5' and approximately 6.7'-7.7' deep on or about May 3, 2017, and at times prior thereto, had not been removed when the presence of information that clearly showed hazards were present. NOTE: Abatement certification AND supporting documentation are required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2017-11-01 |
Abatement Due Date |
2017-11-02 |
Current Penalty |
8873.0 |
Initial Penalty |
88724.0 |
Contest Date |
2017-11-15 |
Final Order |
2019-06-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation are not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c) of this section. a) The employer does not protect each employee in its trenches by properly sloping or using appropriate protective systems. This violation was most recently observed along Myrtle Avenue between 11th Street and 12th Street in Boise, where two employees of Alta Construction, Inc. were working in an excavation approximately 7.6' wide by approximately 80' long and approximately 6.7' - 7.7' deep. Employees were working in the east portion of the excavation, which was also the deepest portion, and approximately 6' away from a busy road leading into downtown. NOTE: Abatement certification AND supporting documentation are required for this item. |
|
|
341827871
|
1032500
|
2016-10-11
|
3050 E JEWELL ST, MERIDIAN, ID, 83642
|
|
Inspection Type |
Monitoring
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-10-11
|
Emphasis |
N: TRENCH
|
Case Closed |
2016-10-17
|
|
339847162
|
1032500
|
2014-07-10
|
USTICK RD FROM CLOVERDALE TO 5 MILE, GARDEN CITY, ID, 83714
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-07-10
|
Emphasis |
P: CTARGET, N: CTARGET
|
Case Closed |
2014-10-09
|
|
339012585
|
1032500
|
2013-04-17
|
12601 W. BRIDGER ST., BOISE, ID, 83713
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-04-17
|
Emphasis |
L: IDCON, P: IDCON
|
Case Closed |
2013-05-07
|
Related Activity
Type |
Inspection |
Activity Nr |
901256 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
901290 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
901280 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
901303 |
Safety |
Yes |
|
|
338926140
|
1032500
|
2013-02-28
|
VARIOUS BOISE STATE UNIVERSITY, BOISE, ID, 83706
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-02-28
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2013-03-01
|
|
338925233
|
1032500
|
2013-02-28
|
1453 UNIVERSITY DRIVE BOISE STATE UNIVERSITY, BOISE, ID, 83706
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-02-28
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2013-03-01
|
|
334447976
|
1032500
|
2012-05-24
|
3201 AIRPORT WAY, BOISE, ID, 83709
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2012-05-24 |
Emphasis |
L: FALL, N: CTARGET |
Case Closed |
2012-05-25 |
|
330985557
|
1032500
|
2011-09-08
|
3676 E WARM SPRINGS RD, BOISE, ID, 83716
|
|
Inspection Type |
Prog Related |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2011-09-08 |
Emphasis |
N: CTARGET |
Case Closed |
2011-09-08 |
|
330927716
|
1032500
|
2011-07-27
|
1565 N. WILDWOOD WAY, BOISE, ID, 83713
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2011-07-27 |
Emphasis |
N: CTARGET, N: TRENCH |
Case Closed |
2012-01-18 |
Related Activity
Type |
Inspection |
Activity Nr |
92763 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
92774 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260200 G01 |
Issuance Date |
2011-08-23 |
Abatement Due Date |
2011-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2011-09-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.200(g)(1): Construction areas were not posted with legible traffic signs at points of hazards: a) East bound lane at shoulder/road right-a-way; On or about 7/27/11 and at times prior thereto, an advanced warning sign alerting approaching vehicles to the presense of a backhoe/loader operating in close proximity to the active roadway was not provided. Note: Abatement certification IS required for this item. |
|
|
330923475
|
1032500
|
2011-06-07
|
HARRIS RANCH FIRE STATION 315 PROJECT, BOISE, ID, 83701
|
|
Inspection Type |
Unprog Other |
Scope |
NoInspection |
Safety/Health |
Safety |
Close Conference |
2011-06-07 |
Case Closed |