Search icon

KNIGHT REFRIGERATED, LLC

Company Details

Name: KNIGHT REFRIGERATED, LLC
Jurisdiction: Idaho
Legal type: Foreign Limited Liability Company
Status: Active-Existing
Date of registration: 23 Aug 2006 (19 years ago)
Financial Date End: 31 Aug 2025
Entity Number: 172755
Place of Formation: ARIZONA
File Number: 172755
Principal Address: 20002 NORTH 19TH AVENUE PHOENIX, AZ 85027
Mailing Address: 2200 SOUTH 75TH AVENUE PHOENIX, AZ 85043

Agent

Name Role Address
C T CORPORATION SYSTEM Agent 1555 W SHORELINE DR, STE 100, BOISE, ID 83702

Manager

Name Role Address Appointed On
Knight Transportation Inc Manager 2002 W WAHALLA LANE, PHOENIX, AZ 85027 2020-08-27

Member

Name Role Address Appointed On
Knight Transportation Inc. Member 2200 SOUTH 75TH AVENUE, PHOENIX, AZ 85043 2024-07-12

Filing

Filing Name Filing Number Filing date
Annual Report 0005818597 2024-07-12
Annual Report 0005375922 2023-08-31
Registered Agent Name/Address Change (mass change) 0004894201 2022-09-12
Annual Report 0004845027 2022-08-04
Annual Report 0004392344 2021-08-25
Annual Report 0003980486 2020-08-27
Annual Report 0003597759 2019-08-19
Annual Report 0001603387 2018-08-20
Annual Report 0001603386 2017-11-02
Annual Report 0001603385 2016-06-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
332822345 1032500 2012-03-14 1795 NORTH HOLMES, IDAHO FALLS, ID, 83401
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-03-14
Emphasis N: SSTARG11
Case Closed 2012-07-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100106 E06 II
Issuance Date 2012-05-29
Abatement Due Date 2012-06-19
Current Penalty 1200.0
Initial Penalty 2295.0
Final Order 2012-07-05
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(e)(6)(ii): Class I liquids were dispensed into containers where the nozzle and container were not electrically interconnected. a) South wall of maintenance shop: On March 14, 2012 and at times prior thereto transferring of methanol, a Class 1B flammable liquid, from one barrel to another was done without the protection of grounding or bonding to minimize the hazard of static electricity. Note ) Abatement certification IS required for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19100037 B02
Issuance Date 2012-05-29
Abatement Due Date 2012-06-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-05
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(b)(2) Each exit was not clearly visible and marked by a sign reading "Exit": a) Wash bay: On March 14, 2012 and at times prior thereto the exit sign above the exit door had been removed. Note) Abatement certification IS required for this item.
Citation ID 02002
Citaton Type Other
Standard Cited 19100178 L06
Issuance Date 2012-05-29
Abatement Due Date 2012-06-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-05
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: a) Maintenance shop: On March 14, 2012 and at times prior thereto employees operating powered industrial trucks (forklifts) had not evaluated and certified by the employer to ensure safe operation and material handling. Note) Abatement certification IS required for this item.
Citation ID 02003
Citaton Type Other
Standard Cited 19100147 C01
Issuance Date 2012-05-29
Abatement Due Date 2012-06-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-05
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment will be isolated from the energy source and rendered inoperative: a) Maintenance shop: On March 14, 2012 and at times prior thereto the employer had not developed and implemented an energy control program for the maintenance shop, which adressed potential sources of energy which may include, but is not limited to, disconnecting the semi-truck battery before any maintenance is performed. Note) Abatement certification IS required for this item.
Citation ID 02004
Citaton Type Other
Standard Cited 19100215 B09
Issuance Date 2012-05-29
Abatement Due Date 2012-06-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-05
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceed one-fourth inch: a) South wall of maintenance shop: On March 14, 2012 and at times prior thereto each of the adjustable tongue guards on the Dewalt bench grinder were 1 inch away from the grinding wheel. Note) Abatement certification IS required for this item.
Citation ID 02005
Citaton Type Other
Standard Cited 19100253 B04 I
Issuance Date 2012-05-29
Abatement Due Date 2012-06-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-05
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material including reserve stocks of carbide and acetylene: a) South east wall of trailer shop: On March 14, 2012 and at times prior thereto reserve cyclinders of oxygen and acetylene were stored together. It was not known if these cylinders were empty or full. Note) Abatement certification is required for this item.
Citation ID 02006
Citaton Type Other
Standard Cited 19101200 E01 I
Issuance Date 2012-05-29
Abatement Due Date 2012-06-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-05
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1)(i): The employer did not have a list of the hazardous chemicals known to be present and use an identity that is referenced on the appropriate material safety data sheet: a) Maintenance shop: On March 14, 2012 and at times prior thereto the employer did not develop and maintain a list of chemicals currently used by employees in the maintenance shop. Note) Abatement certification IS required for this item.

Date of last update: 01 Apr 2025