347913808
|
1032500
|
2024-12-04
|
485 EAST 3RD STREET, WEISER, ID, 83672
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-12-04
|
Emphasis |
L: FALL, N: CTARGET, P: CTARGET
|
Related Activity
Type |
Inspection |
Activity Nr |
1791379 |
Safety |
Yes |
|
|
346579329
|
1032500
|
2023-03-21
|
8000 S FEDERAL WAY, BOISE, ID, 83716
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-21
|
Case Closed |
2023-07-07
|
Related Activity
Type |
Inspection |
Activity Nr |
1658050 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1657929 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2023-06-08 |
Abatement Due Date |
2023-07-06 |
Current Penalty |
3346.7 |
Initial Penalty |
4781.0 |
Final Order |
2023-06-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On March 21, 2023, employees cut 1 1/2-inch floor tiles with a 5 1/4-inch unguarded MA615 band saw blade . Note: Abatement certification is required for this item. |
|
|
344810452
|
1032500
|
2020-06-26
|
10255 W OVERLAND DRIVE, BOISE, ID, 83709
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-06-26
|
Emphasis |
L: IDCON, P: IDCON
|
Case Closed |
2022-03-12
|
Related Activity
Type |
Inspection |
Activity Nr |
1481027 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1481054 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19260405 J01 I |
Issuance Date |
2020-09-21 |
Abatement Due Date |
2020-10-16 |
Current Penalty |
4048.0 |
Initial Penalty |
4048.0 |
Final Order |
2020-10-19 |
Nr Instances |
4 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact: a) On or about June 26, 2020 and at times prior thereto employees were exposed to electrical hazards while installing metal framing materials around exposed live 110V/20A where the outlet boxes were not covered. NOTE-Abatement certification is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19260021 B02 |
Issuance Date |
2020-09-21 |
Abatement Due Date |
2020-10-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-10-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury. a) On or about June 26, 2020 and at times prior thereto employees were exposed to electrical hazards while installing metal framing materials around exposed live 110V/20A where the outlet boxes were not covered, and employees were not trained to recognize the hazards. NOTE-Abatement certification is required for this item. |
|
|
339936296
|
1032500
|
2014-07-15
|
415 SOUTH 9TH STREET, BOISE, ID, 83702
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-07-15
|
Emphasis |
L: IDCON, P: IDCON
|
Case Closed |
2014-07-15
|
|
336543384
|
1032500
|
2012-09-20
|
EDGEMEADE FACILITY, MOUNTAIN HOME, ID, 83647
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-09-20
|
Emphasis |
L: FALL, N: CTARGET
|
Case Closed |
2013-01-15
|
Related Activity
Type |
Inspection |
Activity Nr |
655118 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
653918 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 C01 II |
Issuance Date |
2012-11-30 |
Abatement Due Date |
2012-12-27 |
Current Penalty |
1071.0 |
Initial Penalty |
2142.0 |
Final Order |
2012-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(1)(ii): Guys, ties, and braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet or less thereafter for scaffolds 3 feet wide or less, and every 26 feet or less thereafter for scaffolds greater than 3 feet wide. Such guys, ties and braces were not installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (measured from one end [not both] towards the other): a) East side scaffold: On September 20, 2012, and times prior thereto, employees were working on the top platform at a working height of approximately 31 feet on a 48 inch wide, 14 foot long, tubular welded frame scaffold that did not have a vertical tie at both ends of the scaffold at 16 feet in accordance with the 4:1 height requirement. Note: Abatement certification is required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2012-11-30 |
Abatement Due Date |
2012-12-27 |
Current Penalty |
1339.0 |
Initial Penalty |
2678.0 |
Final Order |
2012-12-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) East side scaffold: On September 20, 2012, and times prior thereto, employees were working on a scaffold at a height of approximately 31 feet that did not have guard rails installed on the ends of the platform. Note: Abatement certification is required for this item. |
|
|
331093690
|
1032500
|
2011-11-22
|
520 S. EAGLE RD., MERIDIAN, ID, 83642
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-11-22
|
Emphasis |
L: FALL, L: IDCON
|
Case Closed |
2012-02-02
|
Related Activity
Type |
Inspection |
Activity Nr |
109374 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
109361 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
109381 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
109382 |
Safety |
Yes |
|
|
313349763
|
1032500
|
2009-09-17
|
827 E. PARK BLVD, BOISE, ID, 83712
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-09-17
|
Emphasis |
L: IDCON, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT
|
Case Closed |
2009-10-08
|
|