Inspection Type |
Unprog Other
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-10-03
|
Emphasis |
N: FALL
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2024-10-31 |
Abatement Due Date |
2024-11-13 |
Current Penalty |
1512.0 |
Initial Penalty |
3042.0 |
Final Order |
2024-11-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) On October 3rd, 2024 employees were exposed to head injuries while working on the ground below framers on the roof. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2024-10-31 |
Abatement Due Date |
2024-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-11-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1):The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On October 3, 2024 and times prior, employees using a pneumatic nail gun to install roofing material and a circular saw to cut wood were not wearing eye protection. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-10-31 |
Abatement Due Date |
2024-11-13 |
Current Penalty |
2281.0 |
Initial Penalty |
4563.0 |
Final Order |
2024-11-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On October 3, 2024, employees working on the roof of a new single-family building was using an A-frame ladder to access and exit the roof. The ladder was positioned below the access point by at least 2 feet. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2024-10-31 |
Abatement Due Date |
2024-11-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-11-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13):The top or step of a stepladder was used as a step: (a) On October 3, 2024, employees used the top step of an A-frame ladder to access and exit the roof. Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-10-31 |
Abatement Due Date |
2024-11-13 |
Current Penalty |
6387.0 |
Initial Penalty |
10646.0 |
Final Order |
2024-11-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On October 3, 2024, employees were exposed to falls between 10 and 23 feet to the ground below while performing framing activities. Hernandez Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1693827, citation number 1, item number 1a and was affirmed as a final order on February 9, 2024, with respect to a workplace located at 2438 Vizcaya Way, Eagle, ID 83616. Abatement Note: Abatement certification and documentation is required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
|
Inspection Type |
Unprog Other
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-08-25
|
Emphasis |
N: FALL
|
Case Closed |
2024-03-25
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-01-09 |
Abatement Due Date |
2024-02-05 |
Current Penalty |
2009.0 |
Initial Penalty |
2009.0 |
Final Order |
2024-02-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). (a)On August 25, 2023, employees were exposed to falls from a height of 11.2 feet while framing the roof of a residential home. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 B01 |
Issuance Date |
2024-01-09 |
Abatement Due Date |
2024-02-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. (a)On August 25, 2023, employees were exposed to falls from a height of 11.2 feet while framing the roof of a residential home. |
|
|