Search icon

SF PLASTER AND STUCCO, LLC

Company Details

Name: SF PLASTER AND STUCCO, LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Inactive-Dissolved
Date of registration: 13 Apr 2006 (19 years ago)
Financial Date End: 30 Apr 2018
Date dissolved: 19 Jan 2018
Entity Number: 160599
Place of Formation: IDAHO
File Number: 0000160599
ZIP code: 83687
County: Canyon County
Principal Address: 10885 SAFFRON DR NAMPA, ID 83687

Filing

Filing Name Filing Number Filing date
Statement of Dissolution 0000760152 2018-01-19
Annual Report 0001550409 2017-03-29
Annual Report 0001550408 2016-02-23
Annual Report 0001550407 2015-02-22
Annual Report 0001550406 2014-02-08
Annual Report 0001550405 2013-02-12
Application for Reinstatement 0001550404 2012-05-24
Application for Reinstatement 0000760151 2012-05-21
Application for Reinstatement 0001550403 2009-10-05
Application for Reinstatement 0000760150 2009-10-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
332835891 1032500 2012-03-27 15556 NORTH KODEE WAY, NAMPA, ID, 83651
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2012-03-27
Emphasis L: FALL, L: RESCON
Case Closed 2016-07-29

Related Activity

Type Inspection
Activity Nr 283524
Safety Yes
Type Inspection
Activity Nr 283584
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2012-04-12
Abatement Due Date 2012-04-13
Current Penalty 1440.0
Initial Penalty 1440.0
Final Order 2012-05-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) Main and side facade areas of the structure, at the ground, 1st and 2nd level of scaffold: On or about March 27, 2012, and at times prior thereto, employees performing stucco work were walking/working below other workers on a tubular welded scaffold without wearing a protective helmet. Note: Abatement certification IS required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 H02
Issuance Date 2012-04-12
Abatement Due Date 2012-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(2): Where there was a danger of tools, materials, or equipment falling from a scaffold and striking employees below, the provisions of paragraphs (h)(2)(i) - (v) of this section were not followed: a) Main entrance of the structure: On or about March 27, 2012, and at times prior thereto, other subcontractor's employees were walking under the tubular welded scaffold being utilized for stucco work that was lacking toe-boards or other protective means to the entrance of the structure. Note: Abatement certification IS required for this item.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B04
Issuance Date 2012-04-12
Abatement Due Date 2012-04-13
Current Penalty 1440.0
Initial Penalty 1440.0
Final Order 2012-05-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(4): Each end of a platform, which was not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support by at least 6 inches: a) Main and side facade areas of the structure, at all levels of the scaffold; On or about March 27, 2012, and at times prior thereto, four employees performing stucco work were utilizing tubular welded frame scaffold that had unsecured planks bridging across from one stand of scaffold to another. One end of the planks did not extend at least 6 inches beyond their support. Note: Abatement certification IS required for this item.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 B03 II
Issuance Date 2012-04-12
Abatement Due Date 2012-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(3)(ii): The maximum distance from the face for plastering and lathing operations exceeded 18 inches (46 cm). a) Main entrance area of the structure, left and right sides of entry, at all levels of the scaffold; On or about March 27, 2012, and at times prior thereto, four employees performing stucco work were utilizing tubular welded frame scaffold where sections of the scaffold was not within 18 inches of the structure's facade. Note: Abatement certification IS required for this item.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-04-12
Abatement Due Date 2012-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. (a) Main and side facade areas of the structure, at the 2nd level of the scaffold; On or about March 27, 2012, and at times prior thereto, four employees performing stucco work were utilizing tubular welded scaffold that was missing and/or had inadequate guardrails and/or end-rails. Note: Abatement certification IS required for this item.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2012-04-12
Abatement Due Date 2012-05-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-08
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Main and side facade areas of the structure, at the ground, 1st and 2nd level of scaffold; On or about March 27, 2012, and at times prior thereto, four employees performing stucco work from tubular welded scaffold demonstrated a lack of understanding and recognition of the potential hazards associated with deficiencies including but not limited to, inadequate/missing guardrails and/or end-rails, inadequate bracing and platforms. and the means for proper access/egress. Note: Abatement certification IS required for this item.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2012-04-12
Abatement Due Date 2012-04-13
Current Penalty 1440.0
Initial Penalty 1440.0
Final Order 2012-05-08
Nr Instances 3
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Main and side facade areas of the structure, at all levels of the scaffold; On or about March 27, 2012, and at times prior thereto, four employees performing stucco work were climbing the end frames of the tubular welded frame scaffold as a means of access. b) Main and side facade areas of the structure, at all levels of the scaffold; On or about March 27, 2012, and at times prior thereto, four employees performing stucco work were climbing the crossbracing of the tubular welded frame scaffold as a means of access. c) Main and side facade areas of the structure, at the 1st level of the scaffold; On or about March 27, 2012, and at times prior thereto, an employee performing stucco work jumped from the tubular welded frame scaffold down to the ground. Note: Abatement certification IS required for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19260451 C02
Issuance Date 2012-04-12
Abatement Due Date 2012-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-05-08
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) Main and side facade areas of the structure, at the ground level of scaffold; On or about March 27, 2012, and at times prior thereto, four employees performing stucco work were utilizing a tubular welded scaffold that was missing numerous base plates and/or mud sills. Note: Abatement certification IS required for this item.

Date of last update: 23 Sep 2024

Sources: Idaho Secretary of State