Search icon

CAMPBELL'S SIDING & WINDOWS

Company Details

Name: CAMPBELL'S SIDING & WINDOWS
Jurisdiction: Idaho
Legal type: Assumed Business Name
Status: Inactive-Cancelled
Date of registration: 01 Jun 2001 (24 years ago)
Entity Number: 149134
Place of Formation: IDAHO
File Number: 0000149134
ZIP code: 83642
County: Ada County
Mailing Address: 124 NW 10TH ST STE 102 MERIDIAN, ID 83642

Filing

Filing Name Filing Number Filing date
Cancellation of Certificate of Assumed Business Name 0000749674 2017-03-16
Initial Filing 0000149134 2001-06-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
336576780 1032500 2012-09-26 3743 W. TAYJAN, POST FALLS, ID, 83854
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-09-27
Emphasis N: CTARGET, P: CTARGET
Case Closed 2014-12-08

Related Activity

Type Inspection
Activity Nr 657658
Safety Yes
Type Inspection
Activity Nr 657679
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260304 I01
Issuance Date 2013-02-13
Abatement Due Date 2013-03-12
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees were using a 10 inch Ryobi table saw, serial number XX093451698, model BTS16, to cut siding. The blade guards were removed. This condition exposed employees to amputation and struck by hazards.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2013-02-13
Abatement Due Date 2013-02-26
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees assembled an aluminum Werner Pump Jack and a frame supported scaffold without installing mud sills or on a stable surface. The scaffolds were being utilized and employees were observed on the scaffold. This condition exposed employees to a fall hazard of up to 28 feet.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2013-02-13
Abatement Due Date 2013-02-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees assembled an aluminum Werner Pump Jack supported scaffold without ensuring the scaffold supports and planking were plumb as required by the manufacturer. The scaffolds were being utilized and employees were observed on the scaffold. This condition exposed employees to a fall hazard of up to 28 feet.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2013-02-13
Abatement Due Date 2013-02-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees erected an aluminum Werner Pump Jack Scaffold without having the scaffold inspected for hazards by a competent person trained to recognize hazards associated with scaffolding. The scaffold was being utilized and employees were observed on the scaffold that was not equipped with guard rails, was not supported sufficiently, and did not have toeboards. This condition exposed employees to a fall hazard of 28 feet.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2013-02-13
Abatement Due Date 2013-02-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees erected an aluminum Werner Pump Jack Scaffold without the supervision of a competent person. The scaffold was being utilized and employees were observed on the scaffold that was not equipped with guard rails, was not supported sufficiently, and did not have toeboards. This condition exposed employees to a fall hazard of 28 feet.
Citation ID 01002E
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2013-02-13
Abatement Due Date 2013-02-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employee was observed working on a Pump Jack Scaffold approximately 28 feet above ground level. Scaffold was not secured at the bottom or any points in between to prevent swaying and displacement to maintain plumb. This condition exposed the employee to a fall hazard of 28 feet.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2013-02-13
Abatement Due Date 2013-02-26
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employee was observed working on a Pump Jack Scaffold approximately 28 feet above ground level. Scaffold did not have gaurdrails installed. This condition exposed the employee to a fall hazard.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-02-13
Abatement Due Date 2013-03-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, the employer did not ensure that each employee performing work on a scaffold was trained to recognize the hazards associated with the type of scaffold in use. This condition exposed employees to a fall hazard.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2013-02-13
Abatement Due Date 2013-03-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, the employer did not ensure that each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold was trained by a competent person to recognize any hazards associated with the work in question. This condition exposed employees to fall hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 H01
Issuance Date 2013-02-13
Abatement Due Date 2013-02-26
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, Employees erected an aluminum Werner Pump Jack Scaffold without the use of toeboards, netting or similar method to prevent objects from falling on employees working below. This condition exposed employees to a struck by hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260404 F06
Issuance Date 2013-02-13
Abatement Due Date 2013-03-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-03-13
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. 3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employer did not ensure that the path to ground from circuits, equipment, or enclosures was permanent and continuous. Two instances were observed. This condition exposed employees to an electrical shock hazard. (a) A 10 inch, 120V 15A, Ryobi table saw, serial number XX093451698, model BTS16 was missing the ground plug. (b) A 7 inch, 120V 13A Skilsaw Circular (Worm Drive) saw, serial number H4862, model HD77 was missing the ground plug.
306435652 1032500 2003-11-06 LIBERTY & BETHEL, BOISE, ID, 83706
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2003-11-06
Emphasis L: FALL
Case Closed 2003-11-06
305516296 1032500 2003-03-07 I84 FREEWAY MONUMENT MEADOWLAKE VILLAGE, MERIDIAN, ID, 83642
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2003-03-07
Emphasis L: FALL
Case Closed 2003-07-15

Related Activity

Type Referral
Activity Nr 200237907
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2003-03-17
Abatement Due Date 2003-03-21
Current Penalty 750.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2003-03-17
Abatement Due Date 2003-03-21
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 B08
Issuance Date 2003-03-17
Abatement Due Date 2003-03-21
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2003-03-17
Abatement Due Date 2003-03-21
Nr Instances 2
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
Citation ID 01001E
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2003-03-17
Abatement Due Date 2003-03-21
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
Citation ID 01001F
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2003-03-17
Abatement Due Date 2003-03-21
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2003-03-17
Abatement Due Date 2003-03-21
Current Penalty 300.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 02
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2003-03-17
Abatement Due Date 2003-03-21
Current Penalty 750.0
Initial Penalty 1500.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
305511594 1032500 2002-06-07 6355 N. ULMER ST., BOISE, ID, 83703
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2002-06-07
Emphasis L: IDCON, S: CONSTRUCTION
Case Closed 2002-06-07

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
877374 Intrastate Non-Hazmat - 0 - 2 1 Private(Property)
Legal Name CAMPBELL'S SIDING & WINDOWS
DBA Name -
Physical Address 124 N W 10TH STE 102, MERIDIAN, ID, 83642, US
Mailing Address 124 N W 10TH STE 102, MERIDIAN, ID, 83642, US
Phone (208) 887-6033
Fax (208) 887-6455
E-mail -

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 23 Sep 2024

Sources: Idaho Secretary of State