Search icon

MOBILE COMPONENT DISTRIBUTORS, INC.

Company Details

Name: MOBILE COMPONENT DISTRIBUTORS, INC.
Jurisdiction: Idaho
Legal type: General Business Corporation (D)
Status: Inactive-Dissolved
Date of registration: 22 May 1972 (53 years ago)
Financial Date End: 31 May 2019
Date dissolved: 26 Oct 2018
Entity Number: 148543
Place of Formation: IDAHO
File Number: 148543
ZIP code: 83705
County: Ada County
Mailing Address: PO BOX 5405 BOISE, ID 83705

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
MOBILE COMPONENT DISTRIBUTORS, INC. PROFIT SHARING PLAN 2016 820301013 2017-04-04 MOBILE COMPONENT DISTRIBUTORS, INC. 14
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1983-05-01
Business code 332900
Sponsor’s telephone number 2083452531
Plan sponsor’s address 450 E. AMITY ROAD, BOISE, ID, 837165204

Signature of

Role Plan administrator
Date 2017-04-04
Name of individual signing HENRY KING
Valid signature Filed with authorized/valid electronic signature
MOBILE COMPONENT DISTRIBUTORS, INC. PROFIT SHARING PLAN 2015 820301013 2016-07-19 MOBILE COMPONENT DISTRIBUTORS, INC. 16
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1983-05-01
Business code 332900
Sponsor’s telephone number 2083452531
Plan sponsor’s address 450 E. AMITY ROAD, BOISE, ID, 837165204

Signature of

Role Plan administrator
Date 2016-07-19
Name of individual signing HENRY KING
Valid signature Filed with authorized/valid electronic signature
MOBILE COMPONENT DISTRIBUTORS, INC. PROFIT SHARING PLAN 2014 820301013 2015-05-12 MOBILE COMPONENT DISTRIBUTORS, INC. 18
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1983-05-01
Business code 332900
Sponsor’s telephone number 2083452531
Plan sponsor’s address 450 E. AMITY ROAD, BOISE, ID, 837165204

Signature of

Role Plan administrator
Date 2015-05-12
Name of individual signing HENRY KING
Valid signature Filed with authorized/valid electronic signature
MOBILE COMPONENT DISTRIBUTORS, INC. PROFIT SHARING PLAN 2013 820301013 2014-08-14 MOBILE COMPONENT DISTRIBUTORS, INC. 19
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1983-05-01
Business code 332900
Sponsor’s telephone number 2083452531
Plan sponsor’s address 450 E. AMITY ROAD, BOISE, ID, 837165204

Signature of

Role Plan administrator
Date 2014-08-14
Name of individual signing HENRY KING
Valid signature Filed with authorized/valid electronic signature
MOBILE COMPONENT DISTRIBUTORS, INC. PROFIT SHARING PLAN 2012 820301013 2013-05-01 MOBILE COMPONENT DISTRIBUTORS, INC. 14
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1983-05-01
Business code 332900
Sponsor’s telephone number 2083452531
Plan sponsor’s address 450 E AMITY RD, BOISE, ID, 837050835

Plan administrator’s name and address

Administrator’s EIN 820301013
Plan administrator’s name MOBILE COMPONENT DISTRIBUTORS, INC.
Plan administrator’s address 450 E AMITY RD, BOISE, ID, 837050835
Administrator’s telephone number 2083368700

Signature of

Role Plan administrator
Date 2013-05-01
Name of individual signing HENRY KING
Valid signature Filed with authorized/valid electronic signature
MOBILE COMPONENT DISTRIBUTORS, INC. PROFIT SHARING PLAN 2011 820301013 2012-07-30 MOBILE COMPONENT DISTRIBUTORS, INC. 14
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1983-05-01
Business code 332900
Sponsor’s telephone number 2083452531
Plan sponsor’s address 450 E AMITY RD, BOISE, ID, 837050835

Plan administrator’s name and address

Administrator’s EIN 820301013
Plan administrator’s name MOBILE COMPONENT DISTRIBUTORS, INC.
Plan administrator’s address 450 E AMITY RD, BOISE, ID, 837050835
Administrator’s telephone number 2083368700

Signature of

Role Plan administrator
Date 2012-07-30
Name of individual signing HENRY KING
Valid signature Filed with authorized/valid electronic signature

Agent

Name Role Address
CHRISTOPHER W CLARK Agent 4414 S GEKELER LN, BOISE, ID 83716

Filing

Filing Name Filing Number Filing date
Articles of Dissolution 0003341708 2018-10-26
Annual Report 0001497129 2018-04-12
Annual Report 0001497128 2017-03-20
Annual Report 0001497127 2016-03-21
Annual Report 0001497126 2015-04-01
Annual Report 0001497125 2014-04-22
Annual Report 0001497124 2013-03-25
Annual Report 0001497123 2012-03-12
Annual Report 0001497120 2011-03-23
Annual Report 0001497119 2010-03-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334992989 1032500 2012-07-03 450 E. AMITY ROAD, BOISE, ID, 83716
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2012-07-03
Case Closed 2013-03-05

Related Activity

Type Complaint
Activity Nr 414071
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2012-10-29
Abatement Due Date 2012-11-28
Current Penalty 1200.0
Initial Penalty 2400.0
Final Order 2012-11-21
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Mechanic Shop: On or about July 3, 2012, a Pacific Hydraulic Press Brake, model 150-10, serial 2186 did not have point of operation guarding Note: Abatement certification IS required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2012-10-29
Abatement Due Date 2012-11-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-21
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Machine Shop: On or about July 3, 2012, and at times prior thereto, Dayton 15" Drill Press, model 4YG14A was not secured from potential movement and/or tip over. Note: Abatement certification IS required for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D02
Issuance Date 2012-10-29
Abatement Due Date 2012-11-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-21
Nr Instances 1
Nr Exposed 20
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): (a) At the job site, a written certification that a hazard assessment of the personal protective equipment requirements in the work place was not available. Employees working at the work site are exposed to hazards such as, but not limited to chemicals, fixed and/or portable equipment and other physical hazards. Abatement certification IS required for this item.
Citation ID 02002
Citaton Type Other
Standard Cited 19100134 K06
Issuance Date 2012-10-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-21
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) Machine Shop: On or about July 3, 2012, and at times prior thereto, the employer provided and permitted the voluntary use of Niosh Particulate Welding Respirators 8212 and did not provide employees with Appendix D to 29 CFR 1910.134. Note: Abatement certification IS NOT required for this item.
Citation ID 02003
Citaton Type Other
Standard Cited 19100147 C01
Issuance Date 2012-10-29
Abatement Due Date 2012-11-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-21
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) At the job site: On or about July 3, 2012, and at times prior thereto, the employer does not have an energy control program developed for equipment which requires documented procedures to address how to effectively de-engergize equipment with multiple sources of energy. Note: Abatement certification IS required for this item.
Citation ID 02004
Citaton Type Other
Standard Cited 19100178 L06
Issuance Date 2012-10-29
Abatement Due Date 2012-12-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-21
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l) (a) The employer did not provide information certifying the training of employees instructed to operate powered industrial trucks. Note: Abatement certification IS required for this item.
Citation ID 02005
Citaton Type Other
Standard Cited 19100303 B02
Issuance Date 2012-10-29
Abatement Due Date 2012-10-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-11-21
Nr Instances 1
Nr Exposed 15
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Shop floor: On or about July 3, 2012, a 4-way junction box was found in use with temporary wiring on the floor. Note: Abatement certification IS required for this item.
101895449 1032500 1987-10-02 450 EAST AMITY ROAD, BOISE, ID, 83705
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1987-10-02
Case Closed 1987-12-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 1987-11-20
Abatement Due Date 1987-12-21
Current Penalty 120.0
Initial Penalty 120.0
Nr Instances 1
Nr Exposed 1
Citation ID 01002
Citaton Type Serious
Standard Cited 19100027 D03
Issuance Date 1987-11-20
Abatement Due Date 1987-12-21
Current Penalty 120.0
Initial Penalty 120.0
Nr Instances 1
Nr Exposed 1
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 1987-11-20
Abatement Due Date 1987-12-21
Current Penalty 240.0
Initial Penalty 240.0
Nr Instances 1
Nr Exposed 3
Citation ID 02001
Citaton Type Other
Standard Cited 19100106 E02 IVA
Issuance Date 1987-11-20
Abatement Due Date 1987-11-25
Nr Instances 1
Nr Exposed 1
Citation ID 02002
Citaton Type Other
Standard Cited 19100215 A04
Issuance Date 1987-11-20
Abatement Due Date 1987-12-01
Nr Instances 1
Nr Exposed 3
Citation ID 02003
Citaton Type Other
Standard Cited 19100215 B09
Issuance Date 1987-11-20
Abatement Due Date 1987-12-01
Nr Instances 1
Nr Exposed 3
Citation ID 02004
Citaton Type Other
Standard Cited 19100219 D01
Issuance Date 1987-11-20
Abatement Due Date 1987-11-25
Nr Instances 2
Nr Exposed 1
Citation ID 02005
Citaton Type Other
Standard Cited 19100219 D01
Issuance Date 1987-11-20
Abatement Due Date 1987-12-01
Nr Instances 1
Nr Exposed 6
Citation ID 02006
Citaton Type Other
Standard Cited 19100242 A
Issuance Date 1987-11-20
Abatement Due Date 1987-11-25
Nr Instances 1
Nr Exposed 6
Citation ID 02007
Citaton Type Other
Standard Cited 19100252 E02 III
Issuance Date 1987-11-20
Abatement Due Date 1987-12-21
Nr Instances 1
Nr Exposed 6
Citation ID 02008
Citaton Type Other
Standard Cited 19100304 F05 V
Issuance Date 1987-11-20
Abatement Due Date 1987-12-01
Nr Instances 1
Nr Exposed 6
Citation ID 02009
Citaton Type Other
Standard Cited 19100305 G01 III
Issuance Date 1987-11-20
Abatement Due Date 1987-11-24
Nr Instances 1
Nr Exposed 6
Citation ID 02010
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 1987-11-20
Abatement Due Date 1987-12-21
Nr Instances 1
Nr Exposed 15
Citation ID 02011
Citaton Type Other
Standard Cited 19101200 F04 I
Issuance Date 1987-11-20
Abatement Due Date 1987-12-21
Nr Instances 1
Nr Exposed 10
Citation ID 02012
Citaton Type Other
Standard Cited 19101200 F04 II
Issuance Date 1987-11-20
Abatement Due Date 1987-12-21
Nr Instances 1
Nr Exposed 10
Citation ID 02013
Citaton Type Other
Standard Cited 19101200 H
Issuance Date 1987-11-20
Abatement Due Date 1987-12-21
Nr Instances 1
Nr Exposed 15
218352003 1032500 1979-02-08 450 AMITY ROAD, Boise, ID, 83705
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1979-02-08
Case Closed 1979-02-23

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100134 A02
Issuance Date 1979-02-15
Abatement Due Date 1979-03-19
Nr Instances 1
Citation ID 01001B
Citaton Type Other
Standard Cited 19100134 B01
Issuance Date 1979-02-15
Abatement Due Date 1979-03-19
Nr Instances 1
Citation ID 01001C
Citaton Type Other
Standard Cited 19100134 B02
Issuance Date 1979-02-15
Abatement Due Date 1979-03-19
Nr Instances 1
Citation ID 01001D
Citaton Type Other
Standard Cited 19100134 B02
Issuance Date 1979-02-15
Abatement Due Date 1979-03-19
Nr Instances 1
Citation ID 01001E
Citaton Type Other
Standard Cited 19100134 C
Issuance Date 1979-02-15
Abatement Due Date 1979-03-19
Nr Instances 1
218317121 1032500 1977-09-14 450 E AMITY RD, Boise, ID, 83705
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 1977-09-14
Case Closed 1977-11-03

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100179 B05
Issuance Date 1977-09-26
Abatement Due Date 1977-09-29
Nr Instances 1
218360170 1032500 1975-11-10 450 EAST AMITY ROAD, Boise, ID, 83705
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 1975-11-10
Case Closed 1975-11-21

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100252 B02 IVD
Issuance Date 1975-11-14
Abatement Due Date 1975-11-26
Nr Instances 1
Related Event Code (REC) Complaint
Citation ID 01002
Citaton Type Other
Standard Cited 19100252 B04 IXC
Issuance Date 1975-11-14
Abatement Due Date 1975-11-26
Nr Instances 1
Related Event Code (REC) Complaint
218359735 1032500 1975-03-03 450 EAST AMITY ROAD, Boise, ID, 83705
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1975-03-04
Emphasis N: TIP
Case Closed 1976-05-17

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100101 B
Issuance Date 1975-03-06
Abatement Due Date 1975-03-13
Nr Instances 1
Citation ID 01002
Citaton Type Other
Standard Cited 19100106 D07 III
Issuance Date 1975-03-06
Abatement Due Date 1975-03-18
Nr Instances 3
Citation ID 01003
Citaton Type Other
Standard Cited 19100157 D02 II
Issuance Date 1975-03-06
Abatement Due Date 1975-03-18
Nr Instances 1
Citation ID 01004
Citaton Type Other
Standard Cited 19100215 A04
Issuance Date 1975-03-06
Abatement Due Date 1975-03-13
Nr Instances 2
Citation ID 01005
Citaton Type Other
Standard Cited 19100215 A09
Issuance Date 1975-03-06
Abatement Due Date 1975-03-25
Nr Instances 2
Citation ID 01006
Citaton Type Other
Standard Cited 19100219 E01 I
Issuance Date 1975-03-06
Abatement Due Date 1975-03-25
Nr Instances 2
Citation ID 01007
Citaton Type Other
Standard Cited 19100309 A 011017
Issuance Date 1975-03-06
Abatement Due Date 1975-03-13
Nr Instances 1
Citation ID 02001
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 1975-03-06
Abatement Due Date 1975-05-08
Current Penalty 50.0
Initial Penalty 500.0
Contest Date 1975-03-15
Nr Instances 1

Date of last update: 31 Mar 2025

Sources: Idaho Secretary of State