Search icon

EVANS FRAMING

Company Details

Name: EVANS FRAMING
Jurisdiction: Idaho
Legal type: Assumed Business Name
Status: Active-Current
Date of registration: 12 Mar 2001 (24 years ago)
Entity Number: 142420
Place of Formation: IDAHO
File Number: 0000142420
ZIP code: 83642
County: Ada County
Mailing Address: 389 CHRISFIELD MERIDIAN, ID 83642

Filing

Filing Name Filing Number Filing date
Initial Filing 0000142420 2001-03-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
338550833 1032500 2013-01-28 CORNER OF FRANKLIN RD. & ORCHARD, BOISE, ID, 83706
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2013-01-28
Emphasis L: FALL
Case Closed 2013-05-28

Related Activity

Type Referral
Activity Nr 773391
Safety Yes
Type Inspection
Activity Nr 857404
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2013-02-13
Abatement Due Date 2013-03-12
Current Penalty 510.0
Initial Penalty 1020.0
Final Order 2013-05-20
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a) East side main floor of building: On January 28, 2013, and times prior thereto, an employee was using a power cut-off saw to cut wood truss bracing without eye protection. Note: Abatement certification is required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2013-02-13
Abatement Due Date 2013-03-12
Current Penalty 850.0
Initial Penalty 1700.0
Final Order 2013-05-20
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Roof truss area South end: On January 28, 2013, and times prior thereto, employees were climbing in and nailing bracing into the new trusses at a height of approximately 19 feet without fall protection. Note: Abatement certification is required for this item.

Date of last update: 23 Sep 2024