344186929
|
1032500
|
2019-07-22
|
1728 S. 2300 E., GOODING, ID, 83330
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-07-22
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2019-12-09
|
Related Activity
Type |
Referral |
Activity Nr |
1477036 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2019-09-24 |
Abatement Due Date |
2019-10-04 |
Current Penalty |
12503.0 |
Initial Penalty |
12503.0 |
Final Order |
2019-11-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Separator Room; On or about July 17, 2019, guarding was insufficient to prevent the operators' hands from being exposed to the paddles of the North Stardrive. NOTE: Abatement certification IS required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 D02 |
Issuance Date |
2019-09-24 |
Abatement Due Date |
2019-10-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-11-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Separator Room; On or about July 17, 2019, the North Stardrive was not turned off or shut down to stop the rotating paddles when employees were performing maintenance. NOTE: Abatement certification IS required for this item. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2019-09-24 |
Abatement Due Date |
2019-10-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-11-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Separator Room; On or about July 17, 2019, a lockout or tagout device was not affixed in order to isolate the North Stardrive prior to performing maintenance. NOTE: Abatement certification IS required for this item. |
|
|
343930574
|
1032500
|
2019-04-09
|
1728 S 2300 N, GOODING, ID, 83330
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-04-11
|
Case Closed |
2019-10-08
|
Related Activity
Type |
Referral |
Activity Nr |
1443354 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2019-07-30 |
Abatement Due Date |
2019-08-23 |
Current Penalty |
13260.0 |
Initial Penalty |
13260.0 |
Final Order |
2019-08-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees from exposure to hazardous chemicals: (a) Whey Plant: A flexible hose attached to the day tank was not used and secured to the tank as designed, exposing workers to 12 to 17 percent sodium hypochlorite. NOTE: Abatement certification and supporting documentation is required. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100132 A |
Issuance Date |
2019-07-30 |
Abatement Due Date |
2019-08-23 |
Current Penalty |
13260.0 |
Initial Penalty |
72930.0 |
Final Order |
2019-08-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) Whey Plant: Workers conducting maintenance activities on the day tank were exposed to 12 to 17 percent sodium hypochlorite. NOTE: Abatement certification and supporting documentation are required for this item. |
|
|
341285039
|
1032500
|
2016-02-26
|
1572 E HIGHWAY 26, RICHFIELD, ID, 83349
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-02-26
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2016-07-21
|
Related Activity
Type |
Referral |
Activity Nr |
1062979 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19100147 C04 I |
Issuance Date |
2016-05-04 |
Abatement Due Date |
2016-05-31 |
Current Penalty |
5100.0 |
Initial Penalty |
5100.0 |
Final Order |
2016-05-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Nutritional Blends Room: On or about February 26, 2016 and at times prior, employees were cleaning the Nutritional Blends Dryer without the rotating equipment being isolated. Abatement certification is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100147 C07 III |
Issuance Date |
2016-05-04 |
Abatement Due Date |
2016-05-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-05-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(iii): The employer did not provide retraining in energy control procedures for employees who underwent a change in their job assignments, a change in machines, equipment or processes that would present new hazard(s) or a change in the energy control procedures: (a) Nutritional Blends Room: On or about February 26, 2016 and at times prior, employees were cleaning the Nutritional Blends Dryer without the rotating equipment being isolated. Abatement certification is required for this item. |
|
|
340457092
|
1032500
|
2015-03-11
|
1572 E HIGHWAY 26, RICHFIELD, ID, 83349
|
|
Inspection Type |
Prog Related
|
Scope |
Records
|
Safety/Health |
Safety
|
Close Conference |
2015-03-11
|
Emphasis |
N: SSTARG14, P: SSTARG14
|
Case Closed |
2015-03-13
|
|
340212703
|
1032500
|
2015-01-28
|
295 SOUTH ASH STREET, BLACKFOOT, ID, 83221
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-01-28
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2015-07-24
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100176 B |
Issuance Date |
2015-02-27 |
Abatement Due Date |
2015-07-01 |
Current Penalty |
3000.0 |
Initial Penalty |
4250.0 |
Final Order |
2015-03-23 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Storage of material was not stable and secure against sliding or collapse: a) Warehouse: On January 28, 20015 and at times prior thereto the industrial rack storage system was not regularly inspected or maintained. Components of the system, including but not limited to load rails, cross beams and rack arms were damaged. Note) Certification of corrective action IS required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2015-02-27 |
Abatement Due Date |
2015-03-11 |
Current Penalty |
1500.0 |
Initial Penalty |
2550.0 |
Final Order |
2015-03-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rests were not of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch: a) Maintenance shop: On January 28, 2015 and at times prior thereto the work rest on the Black & Decker bench grinder (s/n G-297-3771) was not a solid design and showed signs of damage. b) Maintenance shop: On January 28, 2015 and at times prior thereto the work rest on the Black & Decker bench grinder (s/n G-297-3771) was adjusted three quarters of an inch away from the wheel. Note) Certification of corrective action IS required for these items. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2015-02-27 |
Abatement Due Date |
2015-03-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-03-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceed one-fourth inch: a) Maintenance shop: On January 28, 2015 and at times prior thereto the tongue guard on the Black & Decker bench grinder (s/n G-297-3771) was adjusted to 1 and a half inches away from the grinding wheel. Note) Certification of corrective action IS required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19100023 A02 |
Issuance Date |
2015-02-27 |
Current Penalty |
5000.0 |
Initial Penalty |
20000.0 |
Final Order |
2015-03-23 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: a) Conveyor mezzanine: On January 28, 2015 and at times prior thereto employees were exposed to an estimated 9 foot fall hazard to the concrete floor below at the unprotected fixed ladder floor opening. Glanbia Foods, Inc., was previously cited for a violation of this occupational safety and health standard, 1910.23(a)(2), which was contained in OSHA inspection number 313355430, citation number 1, item number 2a and was affirmed as a final order on September 17, 2010, with respect to a workplace located at 1572 East Hwy 26, Richfield, ID, 83349. Note) Certification of corrected action is NOT required for this item. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100219 C04 I |
Issuance Date |
2015-02-27 |
Abatement Due Date |
2015-03-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-03-23 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(4)(i): Projecting shaft ends did not present a smooth edge and end and projected more than one-half the diameter of the shaft: a) BetaVac area: On January 28, 2015 and at times prior thereto, rotating shafts that were not smooth, did not have non-rotating caps in place. b) BetaVac area: On January 28, 2015 and at times prior thereto, a rotating shaft end extended more than one half the diameter of the shaft. Note) Certification of corrective action IS required for this item. |
|
|
339846446
|
1032500
|
2014-07-07
|
1734 S. 2300 E., GOODING, ID, 83330
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-07-10
|
Emphasis |
N: CHEMNEP, P: CHEMNEP
|
Case Closed |
2014-12-09
|
Related Activity
Type |
Inspection |
Activity Nr |
984712 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100119 D03 II |
Issuance Date |
2014-10-23 |
Abatement Due Date |
2014-11-19 |
Current Penalty |
4000.0 |
Initial Penalty |
7000.0 |
Final Order |
2014-11-13 |
Nr Instances |
3 |
Nr Exposed |
370 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. (a) Rooftop relieve valves: On or about July 7, 2014 and at times prior thereto, the employer did not document that relief venting for equipment complied with RAGAGEP in that, the relief vents were not 15 feet about the adjacent grade or roof level. Ammonia equipment includes, but is not limited to, EV-1; EV-2 and EV-3. (b) Site ammonia system: On or about July 7, 2014 and at times prior thereto, the employer did not document that ammonia refrigeration system piping and components were properly identified. Ammonia equipment with missing tags includes, but is not limited to, the HX-1 (three valves) and EV-1; EV-2 and EV3. (c) Site ammonia system: On or about July 7, 2014 and at times prior thereto, the employer did not document that the ceiling and door openings for the machinery room had tight fittings to the outside. The ceiling/wall opening were visible; the overhead door on the south end of the machine room, and man doors on the SW and SE sides of the room were blocked open by water hoses. Note: Abatement certification AND documentation is required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100119 N |
Issuance Date |
2014-10-23 |
Abatement Due Date |
2014-11-19 |
Current Penalty |
2200.0 |
Initial Penalty |
4250.0 |
Final Order |
2014-11-13 |
Nr Instances |
4 |
Nr Exposed |
370 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.119(n): The employer did not establish and implement an emergency plan for the entire plant in accordance with the provisions of 29 CFR 1910.38: (a) Gooding Site main office: On or about July 7, 2014 and at times prior thereto, from approximately 1:30-1:50 pm, emergency radios were not activated in response to a power outage. (b) Gooding Site main office: On or about July 7, 2014 and at times prior thereto, emergency exit lighting was not illuminated with emergency power in response to power outage. (c) Gooding Site facility, Emergency Action Plan: On or about July 7, 2014 and at times prior thereto, the emergency responder list had not been kept up to date. (d) Gooding Site facility, Emergency Action Plan: On or about July 7, 2014 and at times prior thereto, the ammonia monitoring action levels were not consistent throughout the plan, nor were they linked to the evacuation levels. Note: |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100119 O04 |
Issuance Date |
2014-10-23 |
Abatement Due Date |
2014-11-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
370 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.119(o)(4): The employer did not promptly determine and document an appropriate response to each of the findings of the compliance audit, and document that deficiencies had been corrected. (a) Gooding Site: On or about July 7, 2014 and at times prior thereto, the compliance audit recommendation for improving emergency response procedures was not addressed. Note: Abatement certification is required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100146 C02 |
Issuance Date |
2014-10-23 |
Abatement Due Date |
2014-11-19 |
Current Penalty |
150.0 |
Initial Penalty |
200.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a) Steam Vault: On or about July 7, 2014 and at times prior thereto an uncovered vault did not have a sign posted at or near the permit-required confined space to inform employees of the potential danger and prohibit unauthorized entry. Note: Abatement certification AND documentaion is required for this item. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100023 C01 |
Issuance Date |
2014-10-23 |
Abatement Due Date |
2014-11-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. (a)Cheese Plant Roof Top: On or about July 7, 2014 and at times prior thereto, the employer did not provide fall protection for the raised ledge (54 inches) above the adjacent roof level. Note: Abatement certification is required for this item. |
|
Citation ID |
03002 |
Citaton Type |
Other |
Standard Cited |
19100146 C05 II B |
Issuance Date |
2014-10-23 |
Abatement Due Date |
2014-11-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(5)(ii)(B): When an entrance cover was removed, the opening was not promptly guarded by a railing, temporary cover, or other temporary barrier that would prevent an accidental fall through the opening and that would protect each employee. (a)Steam Vault: On or about July 7, 2014 and at times prior thereto the cover to a confined space vault with a leak was left open. Note: Abatement certification is required for this item. |
|
Citation ID |
03003 |
Citaton Type |
Other |
Standard Cited |
19101200 G01 |
Issuance Date |
2014-10-23 |
Abatement Due Date |
2014-11-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-11-13 |
Nr Instances |
1 |
Nr Exposed |
40 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. (a) Machinery Room: On or about July 7, 2014 and at times prior thereto, an SDS (safety data sheet) for Ammonia was not available for the employees working in and around the ammonia machinery room. Note: Abatement certification is required for this item. |
|
|
339473464
|
1032500
|
2013-11-04
|
1734 S 2300 E, GOODING, ID, 83330
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2013-11-06
|
Case Closed |
2013-12-11
|
Related Activity
Type |
Complaint |
Activity Nr |
848208 |
Health |
Yes |
|
|
339417586
|
1032500
|
2013-09-12
|
236 WASHINGTON ST. S, TWIN FALLS, ID, 83301
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-09-12
|
Emphasis |
P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2013-09-12
|
|
339299638
|
1032500
|
2013-08-09
|
1728 S. 2300 E., GOODING, ID, 83330
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-08-09
|
Case Closed |
2013-09-11
|
Related Activity
Type |
Complaint |
Activity Nr |
836724 |
Safety |
Yes |
|
|
332825363
|
1032500
|
2012-03-21
|
1728 S. 2300 E., GOODING, ID, 83330
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2012-03-22
|
Case Closed |
2012-09-13
|
Related Activity
Type |
Complaint |
Activity Nr |
217843 |
Safety |
Yes |
Health |
Yes |
|
|
313355430
|
1032500
|
2010-07-12
|
1572 E. HWY 26, RICHFIELD, ID, 83349
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2010-07-13 |
Emphasis |
N: SSTARG09, S: FALL FROM HEIGHT, S: POWERED IND VEHICLE, N: DUSTEXPL, S: NOISE, S: AMPUTATIONS |
Case Closed |
2011-03-30 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2011-03-20 |
Current Penalty |
4500.0 |
Initial Penalty |
4500.0 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
Hazard |
DUST&FUMES |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100023 A02 |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-10-20 |
Current Penalty |
1875.0 |
Initial Penalty |
1875.0 |
Nr Instances |
4 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100027 D01 I |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-10-20 |
Nr Instances |
4 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100023 D01 III |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-29 |
Current Penalty |
1125.0 |
Initial Penalty |
1125.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100023 D01 IV |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-29 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
01 |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100132 A |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-29 |
Current Penalty |
1125.0 |
Initial Penalty |
1125.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-29 |
Current Penalty |
1125.0 |
Initial Penalty |
1125.0 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-08 |
Current Penalty |
1125.0 |
Initial Penalty |
1125.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-15 |
Current Penalty |
1125.0 |
Initial Penalty |
1125.0 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19101200 H03 III |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-29 |
Current Penalty |
1125.0 |
Initial Penalty |
1125.0 |
Nr Instances |
3 |
Nr Exposed |
15 |
Gravity |
01 |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19101200 F05 I |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 F05 |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-29 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100146 C02 |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100303 F01 |
Issuance Date |
2010-09-03 |
Abatement Due Date |
2010-09-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
308344506
|
1032500
|
2006-01-26
|
1728 S. 2300 E., GOODING, ID, 83330
|
|
Inspection Type |
FollowUp |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2006-01-26 |
Emphasis |
N: AMPUTATE |
Case Closed |
2006-01-27 |
Related Activity
Type |
Inspection |
Activity Nr |
306441759 |
|
|
306441759
|
1032500
|
2004-11-02
|
1728 S. 2300 E., GOODING, ID, 83330
|
|
Inspection Type |
Accident |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2004-11-18 |
Case Closed |
2005-02-07 |
Related Activity
Type |
Accident |
Activity Nr |
361894058 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C02 III |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Current Penalty |
1000.0 |
Initial Penalty |
1800.0 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Current Penalty |
3000.0 |
Initial Penalty |
4500.0 |
Nr Instances |
7 |
Nr Exposed |
10 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 I |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Current Penalty |
3000.0 |
Initial Penalty |
4500.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Current Penalty |
3000.0 |
Initial Penalty |
4500.0 |
Nr Instances |
1 |
Nr Exposed |
50 |
Gravity |
10 |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 II |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Nr Instances |
12 |
Nr Exposed |
50 |
Gravity |
10 |
|
Citation ID |
01004C |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01004D |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 IIIA |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Nr Instances |
2 |
Nr Exposed |
50 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Current Penalty |
5000.0 |
Initial Penalty |
6300.0 |
Nr Instances |
8 |
Nr Exposed |
50 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100242 B |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100147 C05 IID |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101030 F02 IV |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-28 |
Nr Instances |
20 |
Nr Exposed |
20 |
Gravity |
01 |
|
|
306441791
|
1032500
|
2004-11-02
|
1728 S. 2300 E., GOODING, ID, 83330
|
|
Inspection Type |
Unprog Rel |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2004-11-18 |
Emphasis |
N: PSMPQV |
Case Closed |
2005-02-15 |
Related Activity
Type |
Accident |
Activity Nr |
361894058 |
|
Type |
Inspection |
Activity Nr |
306441759 |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100037 E |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-02-18 |
Current Penalty |
675.0 |
Initial Penalty |
1350.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100038 D |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-02-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100165 B02 |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-02-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100120 Q01 |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-31 |
Current Penalty |
2250.0 |
Initial Penalty |
4500.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100120 Q02 I |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-31 |
Nr Instances |
2 |
Nr Exposed |
6 |
Gravity |
10 |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100120 Q02 VIII |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-31 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100120 Q02 X |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-01-31 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100120 Q06 III |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-04-22 |
Current Penalty |
1125.0 |
Initial Penalty |
2250.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
04 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100146 K02 IV |
Issuance Date |
2005-01-05 |
Abatement Due Date |
2005-02-18 |
Current Penalty |
950.0 |
Initial Penalty |
1800.0 |
Nr Instances |
2 |
Nr Exposed |
5 |
Gravity |
02 |
|
|
306438201
|
1032500
|
2004-04-22
|
1572 E. HWY 26, RICHFIELD, ID, 83349
|
|
Inspection Type |
Complaint |
Scope |
Partial |
Safety/Health |
Health |
Close Conference |
2004-04-22 |
Case Closed |
2004-06-16 |
Related Activity
Type |
Complaint |
Activity Nr |
200235612 |
Health |
Yes |
|
|