Search icon

CUEVAS FRAMING LLC

Company Details

Name: CUEVAS FRAMING LLC
Jurisdiction: Idaho
Legal type: Limited Liability Company (D)
Status: Active-Existing
Date of registration: 23 Feb 2005 (20 years ago)
Financial Date End: 28 Feb 2026
Entity Number: 123615
Place of Formation: IDAHO
File Number: 123615
ZIP code: 83607
County: Canyon County
Principal Address: 220 E. PAT LN. CALDWELL, ID 83607
Mailing Address: IRMA E CUEVAS 220 E PAT LN CALDWELL, ID 83607-8999

Agent

Name Role Address
IRMA E CUEVAS Agent 220 E. PAT LN, CALDWELL, ID 83607

Member

Name Role Address Appointed On
Irma E Cuevas Member 220 E PAT LANE, CALDWELL, ID 83607 2021-01-25

Filing

Filing Name Filing Number Filing date
Annual Report 0006081605 2025-01-27
Annual Report 0005564711 2024-01-17
Annual Report 0005085859 2023-01-30
Annual Report 0004582314 2022-01-26
Annual Report 0004142726 2021-01-25
Annual Report 0003758324 2020-01-30
Annual Report 0003422366 2019-02-04
Annual Report 0001392392 2018-01-15
Annual Report 0001392391 2017-01-14
Annual Report 0001392390 2016-01-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340510494 1032500 2015-04-02 4760 STROMBOLI, MERIDIAN, ID, 83642
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-04-03
Emphasis L: RESCON
Case Closed 2016-12-12

Related Activity

Type Referral
Activity Nr 973416
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2015-04-22
Current Penalty 2400.0
Initial Penalty 8000.0
Final Order 2015-06-08
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Jobsite: On or about April 2, 2015 and times prior thereto, employees performing sheathing work did not have a means of fall protection. Note: Abatement certification IS NOT required for this item. The Cuevas Framing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 98655, citation number 1, item number 1a and was affirmed as a final order on November 18, 2011, with respect to a workplace located at Lot 14, Blk 2 Promontory Ridge, Boise, ID 83706. The (employer name) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 106949, citation number 1, item number 1 and was affirmed as a final order on November 18, 2011, with respect to a workplace located at Block 7, Lot 2, N. Chocaya Place, Meridian, Idaho 83642.
Citation ID 01001B
Citaton Type Repeat
Standard Cited 19260503 A02 III
Issuance Date 2015-04-22
Abatement Due Date 2015-05-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-08
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Jobsite: On April 2, 2015 and times prior thereto the responsible person on site and employees performing framing activities did recognize the hazards of sheathing a 6 in 12 pitch roof without any means of fall protection and take actions to minimize or eliminate these hazards. Note) Abatement certification IS required for this item. The Cuevas Framing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.503(a)(2)(iii), which was contained in OSHA inspection number 98655, citation number 1, item number 1b and was affirmed as a final order on November 18, 2011, with respect to a workplace located at Lot 14 Blk 2 Promontory Ridge, Boise, Idaho 83706.
331069492 1032500 2011-09-15 BLOCK 7, LOT 2 N. CHOCAYA PLACE, MERIDIAN, ID, 83642
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2011-09-15
Emphasis L: FALL, L: RESCON
Case Closed 2011-12-12

Related Activity

Type Referral
Activity Nr 81304
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2011-10-20
Current Penalty 650.0
Initial Penalty 1300.0
Final Order 2011-11-18
Nr Instances 3
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) East side of the roof at main entry area; On or about 9/15/11 and at times prior thereto, an employee performing sheathing work did not have a means of fall protection when accessing a ladder for getting up/down from the roof. b) North side of the roof at the west hip area; On or about 9/15/11 and at times prior thereto, a slide guard had not been extended to the roof's rake to provide a means of fall protection for an employee performing sheathing work/trimming sheathing at the hip. c) West side of the structure at the northwest corner; On or about 9/15/11 and at times prior thereto, an employee trimming truss ends/installing a facia board from the top of the exterior wall did not have a means of fall protection. Note: Abatement certification is NOT required for this item.
Citation ID 02001A
Citaton Type Other
Standard Cited 19260403 B01 I
Issuance Date 2011-10-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-11-18
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) Driveway area adjacent to the temporary power riser; On or about 9/15/11 and at times prior thereto, a plastic 4-gang electrical receptacle box was being utilized as a temporary drop box at the end of a flexible cord for providing 120 volt power to various portable tools. Note: Abatement certification is NOT required for this item.
Citation ID 02001B
Citaton Type Other
Standard Cited 19260416 E01
Issuance Date 2011-10-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-11-18
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Driveway area adjacent to the temporary power riser; On or about 9/15/11 and at times prior thereto, the protective cover pulled away from a plug at the end of a flexible cord being utilized for providing 120 volt power to various portable tools. Note: Abatement certification is NOT required for this item.
330986555 1032500 2011-09-09 LOT 14 BLK 2 PROMONTORY RIDGE, BOISE, ID, 83706
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2011-09-09
Emphasis L: RESCON
Case Closed 2012-04-06

Related Activity

Type Referral
Activity Nr 78486
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2011-10-19
Current Penalty 1100.0
Initial Penalty 4200.0
Final Order 2011-11-18
Nr Instances 3
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Jobsite: On September 9, 2011 and times prior thereto employees performed framing activities which included installing trusses, from the exterior top plates with out a fall protection system in place, exposing them to an approximate 20 foot fall hazard. b) Jobsite: On September 9, 2011 and times prior thereto employees performing framing activities on the second floor level were exposed an approximate 13 foot fall hazard at unguarded window openings. c) Jobsite: On September 9, 2011 and times prior thereto employees performing framing activities on the second floor were exposed an approximate nine foot fall hazard at an open sided floor used for access to and from this level. Note) Abatement certification and documentation are NOT required for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A02 III
Issuance Date 2011-10-19
Abatement Due Date 2012-02-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-11-18
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Jobsite: On September 9, 2011 and times prior thereto the responsible person on site and employees performing framing activities did recognize the hazards of working from a exterior top plate, working next to unguarded wall openings, and working near unprotected floor edges, and take actions to minimize or eliminate these hazards. Note) Abatement certification and documentation ARE required for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2011-10-19
Current Penalty 250.0
Initial Penalty 1800.0
Final Order 2011-11-18
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: a) Jobsite: On September 9, 2011 and times prior thereto employees performing framing activities used the top step of an estimated eight foot trestle ladder for access to and from the second floor. Note) Abatement certification is NOT required for this item.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4730277702 2020-05-01 1087 PPP 220 E PAT LANE, CALDWELL, ID, 83607
Loan Status Date 2021-09-23
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 12641
Loan Approval Amount (current) 12641
Undisbursed Amount 0
Franchise Name -
Lender Location ID 12096
Servicing Lender Name Wells Fargo Bank, National Association
Servicing Lender Address 101 N Philips Ave, SIOUX FALLS, SD, 57104-6738
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address CALDWELL, CANYON, ID, 83607-0001
Project Congressional District ID-01
Number of Employees 4
NAICS code 238130
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 12096
Originating Lender Name Wells Fargo Bank, National Association
Originating Lender Address SIOUX FALLS, SD
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 12800.31
Forgiveness Paid Date 2021-08-12

Date of last update: 31 Mar 2025

Sources: Idaho Secretary of State