Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-07-01 |
Abatement Due Date |
2019-07-12 |
Current Penalty |
1800.0 |
Initial Penalty |
2842.0 |
Final Order |
2019-08-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Workers engaged in framing and sheathing a portion of roof ("California overhang") were exposed to fall hazards up to 19 to 20 feet to the ground below. NOTE: Certification of corrective action is required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 |
Issuance Date |
2019-07-01 |
Abatement Due Date |
2019-07-12 |
Current Penalty |
800.0 |
Initial Penalty |
1705.0 |
Final Order |
2019-08-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: (a) Workers using the interior stairs to access the upper floor did not have a handrail. NOTE: Certification of corrective action is required for this item. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2019-07-01 |
Abatement Due Date |
2019-07-12 |
Current Penalty |
1400.0 |
Initial Penalty |
3410.0 |
Final Order |
2019-08-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) A folded A-frame ladder was used to access the roof with only the top and top step above the roofline extending approximately 2 feet. NOTE: Certification of corrective action is required for this item. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2019-07-01 |
Abatement Due Date |
2019-07-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-08-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: (a) An A-frame ladder was used in the closed position to access the roof and not as designed in the fully open position with spreaders locked. For this type of access, a secured extension ladder is more appropriate for the task. NOTE: Certification of corrective action is required for this item. |
|