347124521
|
1032500
|
2023-11-27
|
3633 W FLOATING FEATHER RD, EAGLE, ID, 83616
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-11-27
|
Emphasis |
L: FALL, N: CTARGET, P: CTARGET
|
Case Closed |
2024-05-24
|
Related Activity
Type |
Inspection |
Activity Nr |
1712459 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2024-02-27 |
Abatement Due Date |
2024-03-08 |
Current Penalty |
0.0 |
Initial Penalty |
5807.0 |
Final Order |
2024-03-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury: a) On or about November 27, 2023, and prior to; subcontractor's employees were working on a 6:12 roof during the installation of sheathing and were exposed to falls from 12.2 feet to 28.10 feet. Note* Abatement certification AND documentation is required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2024-02-27 |
Abatement Due Date |
2024-03-08 |
Current Penalty |
2904.0 |
Initial Penalty |
0.0 |
Final Order |
2024-03-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about November 27, 2023 and prior to; subcontractor's employees were working on a 6:12 sloped roof during the installation of sheathing and were exposed to falls from 12.2 feet to 28.10 feet. Note* Abatement certification AND documentation is required for this item. |
|
|
344902226
|
1032500
|
2020-08-27
|
3500 W FRANKLIN RD., MERIDIAN, ID, 83642
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-08-27
|
Emphasis |
L: FORKLIFT, N: CTARGET, P: CTARGET
|
Case Closed |
2020-10-08
|
Related Activity
Type |
Inspection |
Activity Nr |
1490236 |
Safety |
Yes |
|
|
344062831
|
1032500
|
2019-06-05
|
623 UNIVERSITY PLACE, NAMPA, ID, 83686
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-06-05
|
Case Closed |
2019-09-24
|
Related Activity
Type |
Inspection |
Activity Nr |
1406029 |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
1462352 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19261153 G01 |
Issuance Date |
2019-07-23 |
Abatement Due Date |
2019-09-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-08-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan: a) Northwest Nazarene University Student Commons Building Project: On or about June 6, 2019 and at times prior thereto; employer did not ensure a written Exposure Control Plan for subcontractor Masons and Hoddies hand chipping limestone and cutting limestone and cast stone trim pieces using a Husqvarna K760 with wet methods. Note* Abatement certification IS required for this item. |
|
|
341467249
|
1032500
|
2016-05-11
|
333 KELLY PARKWAY, CASCADE, ID, 83611
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-05-11
|
Emphasis |
L: FALL, N: CTARGET, P: CTARGET
|
Case Closed |
2016-10-27
|
Related Activity
Type |
Inspection |
Activity Nr |
1146730 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1146759 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260150 C01 I |
Issuance Date |
2016-07-25 |
Abatement Due Date |
2016-07-29 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2016-08-17 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: (a) On or about May 11, 2016 and at times prior thereto fire extinguishers were not provided in the 7,420 square foot building, where employees were drywalling and installing plumbing materials. NOTE-Abatement certification and documentation are required for this item. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19260405 J01 I |
Issuance Date |
2016-07-25 |
Abatement Due Date |
2016-07-29 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-08-17 |
Nr Instances |
3 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact: (a) On or about May 11, 2016 and at times prior thereto the general contractor and subcontractor employees were exposed to electrical hazards when internal wiring was exposed on outlets and a light switch which had no cover plates, while 110 volt power was applied. Drywall employees were applying drywall compound (mud) next to the outlets with hand held tools, and the Superintendent was plugging in and turning on portable lights. NOTE-Abatement certification and documentation are required for this item. |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19260405 A02 II E |
Issuance Date |
2016-07-25 |
Abatement Due Date |
2016-09-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: (a) On or about May 11, 2016 and at times prior thereto subcontractor employees were exposed to 110 volt electrical hazards when temporary lighting bulbs were not protected from breaking or contact, where employees were drywalling. NOTE-Abatement certification and documentation are required for this item. |
|
Citation ID |
01002C |
Citaton Type |
Other |
Standard Cited |
19260405 A02 II F |
Issuance Date |
2016-07-25 |
Abatement Due Date |
2016-09-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights were suspended by their electric cords when such lights and cords were not designed for suspension: (a) On or about May 11, 2016 and at times prior thereto Subcontractor employees were exposed to 110 volt electric hazards when temporary lighting was suspended with wire wrapped around the cord, suspended from the ceiling, where employees were drywalling. NOTE-Abatement certification and documentation are required for this item. |
|
Citation ID |
01002D |
Citaton Type |
Other |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2016-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) On or about May 11, 2016 and at times prior thereto the general contractor and subcontractor employees were exposed to 110 volt electrical hazards when internal wiring was exposed on an extension cord directly behind the plug, while the cord was being used to provide power to portable lights, where drywall employees were using the lights and where the GC Superintendent was plugging in and turning on power to the lights. NOTE-Abatement certification and documentation are required for this item. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2016-07-25 |
Abatement Due Date |
2016-07-29 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-08-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system: (a) On or about May 11, 2016 and at times prior thereto general contractor and subcontractor employees were exposed to fall hazards greater than 6 feet (6 feet 6 inches) when entering the mechanical room entrance, and while accessing and installing plumbing materials in the mechanical room around a pump pit, where no fall protection was available or used. Note-Abatement certification and documentation are required for this item. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260034 B |
Issuance Date |
2016-07-25 |
Abatement Due Date |
2016-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-17 |
Nr Instances |
2 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.34(b): Exits and access to exits were not marked by a readily visible sign: (a) On or about May 11, 2016 and at times prior thereto exits and access to exits were not marked, where the general contractor employee provided oversight, and where subcontractor employees were drywalling and installing plumbing material in the building. Note-Abatement certification and documentation are required for this item. |
|
|
313351413
|
1032500
|
2009-12-29
|
1355 SOUTH EDGEWATER CIRCLE, NAMPA, ID, 83653
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-12-29
|
Emphasis |
S: ELECTRICAL, S: RESIDENTIAL CONSTR
|
Case Closed |
2010-01-22
|
|
311581359
|
1032500
|
2009-03-05
|
1010 GREENHURST ROAD, NAMPA, ID, 83686
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2009-03-05
|
Emphasis |
S: ELECTRICAL, S: COMMERCIAL CONSTR
|
Case Closed |
2009-03-09
|
|
311581193
|
1032500
|
2009-02-25
|
GRAPE & BIRCH STREETS UNDER LITTLE WOOD RIVER, SHOSHONE, ID, 83352
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Case Closed |
2009-03-05
|
|
311577217
|
1032500
|
2008-09-10
|
3001 12TH AVENUE, NAMPA, ID, 83687
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-09-10
|
Emphasis |
L: FALL, S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT
|
Case Closed |
2008-09-23
|
Related Activity
Type |
Referral |
Activity Nr |
200247443 |
Safety |
Yes |
|
|